Rectangular Valve Flapvat (Series 068)
Transfer valve for large area coating systems e.g. architecture glass and photovoltaic panels/cells. The SolVAT transfer valve is used for load lock, transfer and process chamber isolation.
Specifications Table
| Series Number | 068 |
|---|---|
| Series Name | Rectangular Valve Flapvat |
| Description | The FlapVAT transfer valve is offered for opening heights up to 100mm as a low-cost supplement to the SolVAT transfer valve. The applied valve technology is referred to as a flapper. Compared to other flapper valves the FlapVAT transfer valve has a long gate seal lifetime and is mechanically locked in the closed position. Optionally, it is also available in the version «differential pressure resistant in either direction». |
| Actuator Types | Pneumatic actuator (double acting) |
| Sealing Technology | FlapVAT-System |
| Sealing Gate | FKM (VITON®) |
| Sealing Bonnet | FKM (VITON®) |
| Feedthrough | Rotary feedthrough |
| Leak Rate - Body | < 1 . 10-7 mbar ls-1 |
| Leak Rate - Seat | < 1 . 10-5 mbar ls-1 |
| Nominal inside diameters (ID) in mm (inches) | special - special |
| Body material | Aluminum; Stainless steel |
Dimensional Drawings
Valve
Costumer specified flanges: Groove with O-ringWatercooling in body to cool the flange seals
Vertical mounting orientation
Resistant against 1 bar differential in opening direction
Other sealing materials
Actuator
Rotary feedthrough with pump portActuator with distance piece for temperature reduction
Position indicator
NPN - typeGate
Gate shield for heat radiation or coating from process protectionWatercooling at gate to cool the gate seal